FEATURE
4-Line back-lit LCD text display
Five key menu navigation
Front panel editing with PIN protection
LED and LCD alarm indication
Customisable status screens
Power save mode
Support for up to three remote display units
9 configurable inputs
8 configurable outputs
Flexible sender inputs
Configurable timers and alarms
3 configurable maintenance alarms
Multiple date and time scheduler
Configurable event log (250)
Control logic facilities
Easy access diagnostic page
CAN and Magnetic Pick-up/Alt. sensing
Fuel usage monitor and low fuel alarms
Charge alternator ailure alarm
Manual speed control (on compatible CAN engines)
Manual fuel pump control
Engine exerciser
"Protections disabled" feature
kW overload protection
Reverse power protection
Power monitoring (kW h, kV Ar, kV A h, kV Ar h)
Load switching (load shedding and dummy load outputs)
Unbalanced load protection
Independent Earth Fault trip
True dual mutual standby with load balancing timer
USB connectivity
Backed up real time clock
Fully configurable via Configuration Suite PC software
Configurable display languages
Remote monitoring via Configuration Suite PC software
User selectable RS232 and RS485 communications
Configurable Gencomm pages
Advanced SMS messaging (additional external modem required)
Start & stop capability via SMS messaging
Additional display screens to help with modem diagnostics
Integral PLC editor
AUTO START & AUTO MAINS FAILURE Control ModuleS DSE7310/DSE7320 CONTROLLER Specification |
|
CONTINUOUS VOLTAGE RATING |
8 V to 35 V Continuous |
CRANKING DROPOUTS |
Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries.LEDs and backlight will not be maintained during cranking. |
MAXIMUM OPERATING CURRENT |
340 mA at 12 V, 160 mA at 24 V |
MAXIMUM STANDBY CURRENT |
160 mA at 12 V, 80 mA at 24 V |
CHARGE FAIL/EXCITATION RANGE |
0 V to 35 V |
VOLTAGE RANGE (DSE7320 ONLY) |
15 V - 333 V AC (L-N) |
FREQUENCY RANGE |
3.5 Hz to 75 Hz |
OUTPUT A (FUEL) |
15 A DC at supply voltage |
OUTPUT B (START) |
15 A DC at supply voltage |
OUTPUTS C & D |
8 A 250 V (Volt free) |
AUXILIARY OUTPUTS E,F,G,H |
2 A DC at supply voltage |
GENERATOR VOLTAGE RANGE |
15 V - 333 V AC (L-N) |
FREQUENCY RANGE |
3.5 Hz to 75 Hz |
MAGNETIC PICK UP VOLTAGE RANGE |
+/- 0.5 V to 70 V |
FREQUENCY RANGE |
10,000 Hz (max) |
(DIMENSIONS) OVERALL |
240 mm x 181 mm x 42 mm
9.4”x 7.1”x 1.6”
|
PANEL CUT-OUT |
220 mm x 160 mm 8.7”x 6.3” |
MAXIMUM PANEL THICKNESS |
8 mm 0.3” |
Contact: Jack
Phone: 0086-19906045242
Tel: 0086-592-7161550
Email: sales@aotchina.com