Speed Governor

  • Generator Governor Automatic Control Speed Controller ESD5221
  • Generator Governor Automatic Control Speed Controller ESD5221
  • Generator Governor Automatic Control Speed Controller ESD5221
Generator Governor Automatic Control Speed Controller ESD5221Generator Governor Automatic Control Speed Controller ESD5221Generator Governor Automatic Control Speed Controller ESD5221

Generator Governor Automatic Control Speed Controller ESD5221

  • Model: ESD5220
  • Origin: China
  • Warranty: 1 Year
  • In stock: Yes
  • Product description: Diesel Generator Speed Controller ESD5221 Speed Control Unit is rugged enough to be placed in a control cabinet or engine mounted encosure with other dedicated control equipment. If water, mist or con
  • INQUIRY

Diesel Generator Speed Controller ESD5221 Speed Control Unit is rugged enough to be placed in a control cabinet or engine mounted encosure with other dedicated control equipment. If water, mist or condensation may come in contact with controller, it should be mounted certically. This will allow the fluid to drain away from the speed control unit.

 

ESD5221 built on the basis of the start of the new fuel control and smooth slow start to control the process, these new features can be resolved in the engine to start the process by the rapid filling of black smoke caused by the phenomenon has greatly improved the engine's life . At present,it is very rich, perfect models in the new generators are widely in use.

 

Generator automatic governor speed control unit ESD5221

 Input

 Supply

 12 or 24 VDC Battery System (Transient and Reverse Voltage)

 Polarity

 Negative Ground (Case Isolated)

 Power Consumption

 50 ma continuous plus Actuator current

 Actuator Current Range @77°F 
 (25 °C) - (Inductive Load)

 Min.2.5 Amps; Max. 10Amps continuous

 Speed Sensor Signal

 0.5-120 Volts RMS

 Speed switch Relay 
 Contacts(N.O.and N.C)

 10 Amps

 Performance

 Isochronous Operation/Steady 
 State Stability

 ±0.25% or better

 Speed Range/Governor

 1K to 7.5K Hz continuous

 Speed Drift with Temperature

 ±1% Max

 Idle Adjust CW

 60% of set speed

 Idle Adjust CCW

 Less than 1200 Hz.

 Droop Range

 1-5% regulation

 Droop Adj. Max. (K-L 
 Jumpered)

 400 Hz., ±75Hz. Per 1.0A change

 Droop Adj. Min. (K-L Jumpered)

 15Hz., ±6Hz. Per 1.0A change

 Speed Trim Range

 ±200 Hz

 Remote Variable Speed Range

 500 - 7.5 Hz. Or any part there of Terminal Sensitivity

 Terminal Sensitivity J

 100 Hz., ± 15Hz / Volt @ 5.0 K Impedance

 Terminal Sensitivity L

 735 Hz., ±60 Hz / Volt @ 65 K Impedance

 Terminal Sensitivity N

 148 Hz., ±10 Hz / Volt @ 1 Meg. Impedance

 Terminal Sensitivity P

 10 VDC Supply @ 20 ma Max

 Speed witch adjustment range

 1000-10000HZ

 Environmental

 Ambient Operating 
 Temperature Range

 -40 to +180°F(-40°+85 °C)

 Relative Humidity

 Up to 95%

 All Surface Finishes

 Fungus Proof and Corrosion Resitant

 Reliability

 Vibration

 1G @ 20 to 100 Hz.

 Testing

 100% Functionally Tested

 Physical 

 Dimensions

 See outline (FIGURE 1)

 Weigh1

 1.8 lbs.(820 grams)

 Mounting

 Any position, Vertical Preferred

Scan the qr codeClose