FG Wilson EIM and PCB

  • 12V Generator Control Panel PCB 650-091 for FG Wilson
  • 12V Generator Control Panel PCB 650-091 for FG Wilson
  • 12V Generator Control Panel PCB 650-091 for FG Wilson
  • 12V Generator Control Panel PCB 650-091 for FG Wilson
  • 12V Generator Control Panel PCB 650-091 for FG Wilson
  • 12V Generator Control Panel PCB 650-091 for FG Wilson
12V Generator Control Panel PCB 650-091 for FG Wilson12V Generator Control Panel PCB 650-091 for FG Wilson12V Generator Control Panel PCB 650-091 for FG Wilson12V Generator Control Panel PCB 650-091 for FG Wilson12V Generator Control Panel PCB 650-091 for FG Wilson12V Generator Control Panel PCB 650-091 for FG Wilson

12V Generator Control Panel PCB 650-091 for FG Wilson

  • Model: 650-091
  • Origin: China
  • In stock: yes
  • warranty: 1 year
  • Product description: Generator Controller Board 12V 650-091 Printed Circuit Board for gensets OLYMPLAN-MASSEY FERGUSON 12V.
  • INQUIRY

Green Color 5 Lights Generator 12V Control Panel PCB 650-091

FG WILSON PCB 650-091 with high quality can completely replace the the original one.
If you need the original one, please contacct us for more information.

for Wilson Printed Circuit Board PCB 650-091
1.PCB 650-091 in stock
2.PCB 650-091 professional  manufacture.
3.Factory direct price

The 650-091 Printed Circuit Board for gensets OLYMPLAN-MASSEY FERGUSON 12V.
The 650-092 Printed Circuit Board for gensets OLYMPLAN-MASSEY FERGUSON 24V.

Generator control panel PCB 650-091 Printed Circuit Board 12V/24V

Ensure the MPU (Magnetic Pickup) is installed correctly.


Unscrew and pull out the magnetic pickup that is located near the flywheel of the engine Inspect the magnetic tip and ensure that it is clean and free of debris. Screw the MPU in until the tip makes contact with the top of the flywheel teeth. Back out the magnetic pickup ½ to ¾ of a turn.


EIM (Engine Interface Module)
Turn the ten-turn potentiometer between five to seven turns clockwise or just until you feel a small click - signifying the full span of the pot.
Start the generator set. You will notice the overspeed calibration LED illuminated.

Slowly turn the potentiometer counter-clockwise until the LED just turns off.


As soon as the LED turns off, start to slowly turn back the potentiometer clockwise just until the led starts to flicker.

Scan the qr codeClose
the qr code